Wideband reading lean after free-air calibration
#1
Wideband reading lean after free-air calibration
Hello,
I recalibrated my Innovate MTX-L wideband after a couple of DEs and my AFR numbers are now lean under boost.
Last calibration was at initial install almost a year ago and VE table on my MS2E has been dialed in.
Under full boost (80kpa) I was hitting my AFR target of 11.5 and now seeing values of around 13.
Has anyone else seen this before? Would appreciate any help.
I recalibrated my Innovate MTX-L wideband after a couple of DEs and my AFR numbers are now lean under boost.
Last calibration was at initial install almost a year ago and VE table on my MS2E has been dialed in.
Under full boost (80kpa) I was hitting my AFR target of 11.5 and now seeing values of around 13.
Has anyone else seen this before? Would appreciate any help.