v1.5 upgrade error on Rev MS3 Basic
#1
v1.5 upgrade error on Rev MS3 Basic
I upgraded my Rev-built MS3 Basic from 1.4.1 to the new 1.5 firmware and applied the old settings using the TunerStudio tool. Afterwards I got an error saying "zeros set in baro, air density, or warmup. This won't work."
I went through the tune and verified I'm not using baro correction and my air density and warmup settings are the same as before the upgrade. I also Googled this error message and couldn't find anything. I went back to 1.4.1 and everything is working fine again.
Has anybody else seen this error? Any ideas on how to correct it?
I went through the tune and verified I'm not using baro correction and my air density and warmup settings are the same as before the upgrade. I also Googled this error message and couldn't find anything. I went back to 1.4.1 and everything is working fine again.
Has anybody else seen this error? Any ideas on how to correct it?
#4
Go here, Megasquirt Downloads Firmware and Software - Megasquirt EFI
The Ms Labs MS3 Basic uses the standard firmware.
The Ms Labs MS3 Basic uses the standard firmware.
Last edited by Ivan; 01-28-2017 at 09:18 PM.
#8
you went from an old map, you need to update it to work with newer firmware. those tables it's referencing are in %s, but 100% = no enrichment. those tables USED to be 0 = no enrichment. just go back in and make sure there's no invalid numbers in those tables, even if unused.