save this somewhere and tell it use it: http://boostedmiata.com/MS/msq/firmware/msns-extra.ini
(right click, save link as, save as txt) |
Anyone using TS on a mac?
|
Originally Posted by thesnowboarder
(Post 513733)
Anyone using TS on a mac?
|
AEM and AFR reading
Win7 Home Premium 64bit:
For my AFR Target tables to show up as AFR instead of volts using AEM I had to edit the mainController file in c:\users\Name\My Documents\TunerStudioProjects\Miata\projectCfg\mainController Where Name is your username and Miata is whatever you called your project. Changed these lines per instructions from the sticky thread Look for the following lines in that "page = 7" section: #elif AEM_LINEAR afrBins1 = array, U08, 0, [8x8], "Volts", 0.0196, 0, 0.0, 5.0, 2 You want to make the following changes, which I've highlighted in red: #elif AEM_LINEAR afrBins1 = array, U08, 0, [8x8], "AFR", 0.038666, 255.0, 10.0, 20.0, 1 Also had to either adjust or disable User Account Control. |
Originally Posted by Tremiata
(Post 513741)
Win7 Home Premium 64bit:
For my AFR Target tables to show up as AFR instead of volts using AEM I had to edit the mainController file in c:\users\Name\My Documents\TunerStudioProjects\Miata\projectCfg\mainController Where Name is your username and Miata is whatever you called your project. Also had to either adjust or disable User Account Control. What do you mean by this? |
Well for some reason mine still says there are unit mismatches every time I load up my msq.
|
did you activate the hr_10g firmware in configurator like i keep sayin?
|
Originally Posted by Braineack
(Post 513931)
did you activate the hr_10g firmware in configurator like i keep sayin?
|
Originally Posted by Braineack
(Post 513931)
did you activate the hr_10g firmware in configurator like i keep sayin?
|
it's under the project
|
Originally Posted by Turbo_4
(Post 514271)
There's no configurator option under TS...The only way to get to it is through MS...am I supposed to activate it through ms?
Then under the configuration tab, change the ECU definition to "MS/Extra format hr_10 *******" If you dont have that, select other, then browse to the file you should have downloaded: this one: http://boostedmiata.com/MS/msq/firmw...extra.ini.hr10 |
Okay so I just started a new project and use that hr10 file as my firmare file. I activated it through MS and changed it to the AFR instead of volts. Now when I open my project it does not tell me about the differences. But, if I go in and just load my msq rather than loading the project first it says there is an error.
|
You can put the MSQ in your project folder and it'll load that one.
|
Yeah....If I just click the msq on my desktop is loads under TEMP. So instead I just open up TS, open my specific project, and there you go...no error. Thanks!
|
Yeah, I'm still getting used to the project nuances myself, I still use MT for loading other's files because it's easier to swap between projects with errors and crap.
|
Where exactly are you sticking the msq in your project folder? Just generally in the specific folder or one of the sub-folders? When I open the project if no longer says the name of the msq at the bottom right portion of the screen like it would otherwise.
|
there should be a default or offlinetune .msq file that gets created for each project, so long as you open TS it'll preload the last tune you saved so you shouldnt be clicking on msq files, just open the software and itll already be loaded.
|
Ahhhh okay, I'm still just getting used to this so thanks for being understanding. I'm used to the simplicity of a dtec.
|
Originally Posted by Braineack
(Post 514318)
there should be a default or offlinetune .msq file that gets created for each project, so long as you open TS it'll preload the last tune you saved so you shouldnt be clicking on msq files, just open the software and itll already be loaded.
It's under OPTIONS - PREFERENCES - PERFORM DIFFERENCE REPORT UPON CONNECT. Handy to have on if you like to hand-smooth and make changes in the comfort of your own home while offline or if you are constantly opening other peoples maps in your project. |
Are there just three inc files that you need to copy overto the inc folder in the TS project directory?... Airdenfactor, matfactor, and thermfactor?
|
All times are GMT -4. The time now is 11:47 PM. |