MEGAsquirt A place to collectively sort out this megasquirt gizmo

ms grounds

Thread Tools
 
Search this Thread
 
Old 02-26-2007 | 11:14 PM
  #1  
adbradley's Avatar
Thread Starter
Senior Member
iTrader: (2)
 
Joined: Feb 2006
Posts: 999
Total Cats: 0
From: Mesa, AZ
Default ms grounds

ok i have the the 5 grounds 8,9,10, 11, and 19 all connected to one wire comming from the db37, what pin on the ecu should i connect this to??
Old 02-26-2007 | 11:26 PM
  #2  
Al Hounos's Avatar
Senior Member
 
Joined: Oct 2005
Posts: 1,168
Total Cats: 0
From: Knoxville
Default

stock ecu ground...
Old 02-26-2007 | 11:33 PM
  #3  
adbradley's Avatar
Thread Starter
Senior Member
iTrader: (2)
 
Joined: Feb 2006
Posts: 999
Total Cats: 0
From: Mesa, AZ
Default

whitch one, there are like 4?

2a, 2b, 2c, 2d
Old 02-26-2007 | 11:37 PM
  #4  
mschlang's Avatar
Junior Member
 
Joined: Jun 2006
Posts: 225
Total Cats: 0
From: LV, NV
Default

I ran the ground to the stock grounds on the engine near the CAS and FP regulator. You can never have too good of a ground connection.
Old 02-27-2007 | 07:57 AM
  #5  
ecugrad's Avatar
Junior Member
 
Joined: Feb 2006
Posts: 211
Total Cats: 0
From: Greenville, NC
Default

Originally Posted by mschlang
I ran the ground to the stock grounds on the engine near the CAS and FP regulator. You can never have too good of a ground connection.
I ran mine to roughly the same location.
Old 02-27-2007 | 09:45 AM
  #6  
adbradley's Avatar
Thread Starter
Senior Member
iTrader: (2)
 
Joined: Feb 2006
Posts: 999
Total Cats: 0
From: Mesa, AZ
Default

so pin 8,9,10,11, and 19 on the ms connector can all connect to the ground near the engine??
Old 02-27-2007 | 02:10 PM
  #7  
Arkmage's Avatar
Elite Member
iTrader: (3)
 
Joined: May 2006
Posts: 2,895
Total Cats: 0
From: Houston, TX
Default

I grounded them to one of the stock ecu mounting bolts. Also, what gauge wire did you use for your ground? If you connect all of them together in the DB37 (I did) you need to make sure you have a low enough gauge wire to support all those grounds without noise interference.
Old 02-27-2007 | 02:24 PM
  #8  
cjernigan's Avatar
Elite Member
iTrader: (13)
 
Joined: Oct 2006
Posts: 8,091
Total Cats: 7
From: Atlanta, GA
Default

What would you recommend than arkmage?
Old 02-27-2007 | 02:26 PM
  #9  
adbradley's Avatar
Thread Starter
Senior Member
iTrader: (2)
 
Joined: Feb 2006
Posts: 999
Total Cats: 0
From: Mesa, AZ
Default

i used like a 10 gauge
Old 02-27-2007 | 05:19 PM
  #10  
Arkmage's Avatar
Elite Member
iTrader: (3)
 
Joined: May 2006
Posts: 2,895
Total Cats: 0
From: Houston, TX
Default

Originally Posted by cjernigan
What would you recommend than arkmage?
10-12 ga would be ideal... I wouldn't use anything higher than 14.
Old 02-27-2007 | 05:45 PM
  #11  
adbradley's Avatar
Thread Starter
Senior Member
iTrader: (2)
 
Joined: Feb 2006
Posts: 999
Total Cats: 0
From: Mesa, AZ
Default

done
Old 02-27-2007 | 07:01 PM
  #12  
mazdasly75's Avatar
Newb
 
Joined: Feb 2007
Posts: 43
Total Cats: 0
From: Qc, Canada
Default

I always run the grounds to the battery to avoid spike into the inputs, but as long as there is less than 0.3 ohms in your connection, you are okay.

Last edited by mazdasly75; 03-01-2007 at 03:52 PM.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Full_Tilt_Boogie
Build Threads
84
04-12-2021 04:21 PM
chris101
Miata parts for sale/trade
5
02-19-2016 07:13 PM
interestedofold
Suspension, Brakes, Drivetrain
5
09-29-2015 01:42 PM
btabor
ECUs and Tuning
10
09-28-2015 05:33 PM



Quick Reply: ms grounds



All times are GMT -4. The time now is 05:59 AM.