Megatune isn't reading my wideband AFR correctly after hi res
#1
Megatune isn't reading my wideband AFR correctly after hi res
Before I went to hi-res (was running 29_ before) megatune showed the same AFR as my AEM gauge (it's an AEM linear). After upgrading to hi-res it's now reading ~ .3 AFR lower than the gauge. Anyone know why this might be?
Also, I looked into the equation in Megatune configurator and it looks funny:
AFR = 9.72 + egoADC * 0.038666
which is strange, according to AEM the end points are:
AFR 10.0 at 0V, AFR 19.98 at 5V
I thought the equation should be:
AFR = 10.0 + egoADC(V)*(1.996)
Is the equation in Megasquirt Configurator wrong???
Also, I looked into the equation in Megatune configurator and it looks funny:
AFR = 9.72 + egoADC * 0.038666
which is strange, according to AEM the end points are:
AFR 10.0 at 0V, AFR 19.98 at 5V
I thought the equation should be:
AFR = 10.0 + egoADC(V)*(1.996)
Is the equation in Megasquirt Configurator wrong???
Last edited by fluke; 09-01-2008 at 07:57 PM. Reason: I screwed up my math
#2
you might be on to something...
http://forums.plastikhosting.net/viewtopic.php?t=2221
of course the search feature might have yielded that as it's been discussed here a few times
9.48 seems to be the golden number for me
http://forums.plastikhosting.net/viewtopic.php?t=2221
of course the search feature might have yielded that as it's been discussed here a few times
9.48 seems to be the golden number for me
Thread
Thread Starter
Forum
Replies
Last Post
Zaphod
MEGAsquirt
47
10-27-2018 12:00 AM
stoves
Suspension, Brakes, Drivetrain
5
04-21-2016 04:00 PM