Fixed MegaTune wideband config menu (Innovate users)
#1
Junior Member
Thread Starter
Join Date: Feb 2007
Location: 11368 miles from where i would like to be
Posts: 269
Total Cats: 92
Fixed MegaTune wideband config menu (Innovate users)
I personally think that this should be stickied here :
http://www.msextra.com/viewtopic.php?p=180531#180531
MegaTune has a confusing menu structure that frequently leads to people having the wrong config for their Innovate wideband units. NOT GOOD.
LC-1 is by far more common than LM-1 (at least in DIY circles in my experience) and the Innovate menu item called "Innovate 0 - 5" is for the LM-1 not the LC-1. LC-1 users must use the generic linear option...
That guy just posted a repaired version with the menu item names clarified.
It works! :-)
Fred.
http://www.msextra.com/viewtopic.php?p=180531#180531
MegaTune has a confusing menu structure that frequently leads to people having the wrong config for their Innovate wideband units. NOT GOOD.
LC-1 is by far more common than LM-1 (at least in DIY circles in my experience) and the Innovate menu item called "Innovate 0 - 5" is for the LM-1 not the LC-1. LC-1 users must use the generic linear option...
That guy just posted a repaired version with the menu item names clarified.
It works! :-)
Fred.
#2
Boost Czar
iTrader: (62)
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,729
Total Cats: 4,126
what's confusing about this:
INNOVATE_1_2_LINEAR "Innovate sensor giving 1-2V 10-20:1 AFR"
INNOVATE_0_5_LINEAR "Innovate, PLX 0-5V 10-20:1 AFR"
INNOVATE_LC1_DEFAULT "Innovate LC-1 default, 0-5v = 0.5-1.5 lambda"
INNOVATE_1_2_LINEAR "Innovate sensor giving 1-2V 10-20:1 AFR"
INNOVATE_0_5_LINEAR "Innovate, PLX 0-5V 10-20:1 AFR"
INNOVATE_LC1_DEFAULT "Innovate LC-1 default, 0-5v = 0.5-1.5 lambda"
Thread
Thread Starter
Forum
Replies