DIYAutotune CAN-EGT Setup Error
#1
Junior Member
Thread Starter
iTrader: (2)
Join Date: Sep 2013
Location: Pittsburgh PA
Posts: 266
Total Cats: 7
DIYAutotune CAN-EGT Setup Error
Is there a way to tell if you are actually communicating to the CAN device? I am trying to use DIY's CANEGT and all I get from the CANEGO is the "Default AFR value in case of error" that I program into it. It does not seem obvious to me if the problem is with the connection between the CAGEGT and the MS3, or between the CANEGT and the LC-2 I am trying to use.
#2
SADFab Destructive Testing Engineer
iTrader: (5)
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
The point of the "Default AFR value in case of error" is so that you tell where the error is coming from. If Tunerstudio is displaying that AFR then you know that it is communicating with the CANEGT just fine. The error is between the LC-2 and the CANEGT. Make sure you are using the right port on the LC-2
Also if you were able to set the default error AFR value then you are communicating with the CAN-EGT over CANBus
Also if you were able to set the default error AFR value then you are communicating with the CAN-EGT over CANBus
Thread
Thread Starter
Forum
Replies
Last Post
Carloverx
MEGAsquirt
12
02-16-2019 10:13 PM